Serial no. |
Parameter designation
|
Unit of measure
|
Value
|
||||||
1.
|
Determined speed |
km/h
|
0-25
|
||||||
2.
|
Maximum readin
|
km
|
999
|
||||||
3.
|
Nominal supply voltage |
V
|
24/40-80
|
||||||
4.
|
Supply voltage limit |
V
|
9-27
|
||||||
5.
|
Limit absolute accuracy (within the range of 0 to25 km/h) |
km/h
|
0,5
|
||||||
6.
|
Power consumption |
Wt
|
2,4
|
||||||
7.
|
Average error-free running time, minimum |
h
|
1500
|
||||||
8.
|
Average time of operable state recovery, maximum |
h
|
1
|
||||||
9.
|
Mass |
kg
|
8
|
Serial no. | Designation | Unit of measure | Value |
1. | Environmental temperature | îÑ | 263-308 (-10-+35) |
2. | Relative humidity at a temperature of 308 Ê | % | 98±2 |
3. | Dust content | mg/m3 | no more 300 |
4. | Mechanical load exposure (group Ì25 according to GOST 17516,1) sinusoidal vibration: | ||
- frequency band | Hz |
0,5-100
|
|
- maximum peak amplitude | m/s2 | 10 | |
5. | Single action shocks: | ||
- peak shocks in horizontal direction with acceleration | m/s 2 | 30 | |
- duration | m/s | 2-20 |
Serial no. | Designation |
Quantity, pcs
|
Explosion protection level and kind
|
Protection level
|
Purpose
|
||||||
1. | Sensor
SR .20.000
|
1 | RV1V | IP54 |
Formation of rectangular pulses, with frequency proportionate to the
rotation speed of railway motor
|
||||||
2. | Indicating unit | 1 | RV1V | IP54 |
Displaying in digital form of electric locomotive travelling speed, trail (when the electric locomotive stops)
|